The lights and exhaust fans in the bathroom share a single switch, can one switch be controlled sepa

Updated on Bathroom 2024-08-22
13 answers
  1. Anonymous users2024-01-24

    To control independently, two switches (double open and single control) are required. Connect the live wire to L1 and L2, and disassemble the wires of the two electrical appliances and connect them to L11 and L21 respectively.

  2. Anonymous users2024-01-23

    Yes, brother, it's the same as a lamp that changes light. Press the white light, then the yellow light, and then the turn off. Xuanji is the dimming driver, two outputs, one to connect the lamp, one to the exhaust fan, but the fan, you have to sell the DC to match the power and the output of the lamp.

  3. Anonymous users2024-01-22

    This has to be looked at specifically, mainly how the wiring is arranged.

    If their condition lines are pulled into the switch, then replace the switch with a double open control and it will be simply solved.

    If the switch is just a line of lights and exhaust fans, it will not be easy to do.

  4. Anonymous users2024-01-21

    This is very simple, find an electrician to add a control cable between your switch and the lamp, and then buy a two-control switch to separate the lamp and the exhaust fan.

  5. Anonymous users2024-01-20

    There should be a threading pipe, and it shouldn't be difficult to thread a wire, but if you don't move the line, it shouldn't be.

  6. Anonymous users2024-01-19

    It can be installed with a distributor and can be controlled separately.

  7. Anonymous users2024-01-18

    No, you can install a double switch.

  8. Anonymous users2024-01-17

    Two electrical appliances use a switch to control the opening and closing at the same time, and one more must be connected from the switch to separate the control, that is, the power cord connected to the lamp and the exhaust fan is removed, and then connected to the switch.

  9. Anonymous users2024-01-16

    A single switch separately.

    What if you want to use both the control light and the exhaust fan?

    It is recommended that you change to a double-open panel, and the different types of control lights and exhaust fans will work. You don't have to re-run the line. Your current switch and closure after the lamp and exhaust fan can work normally, it means that these two appliances are connected in parallel, there must be two live wires connected, the two live wires are connected to the two contacts of the double opening, and the two electrical appliances can also share the zero wire.

    If you can't pick it up yourself, you can hire a professional to do it. It's simple.

  10. Anonymous users2024-01-15

    If the wires of your lamp and fan are separated, you can change the switch to a double-open switch.

    If the wires of your lamp and fan are not separated, you will not be able to do so, and you must re-wire.

  11. Anonymous users2024-01-14

    Remove the single-switch switch and see if there are three lines behind it: one live wire (usually red line) and two back lines (usually white), if so, just change a double switch.

    If it is two wires, it will be a little difficult to realize your problem, usually to disassemble the top stringing or install the sub-control switch.

  12. Anonymous users2024-01-13

    It should be possible. Bai such as du fruit is before there is only one open

    If it's off.,Dismantle the switch.,And then re-install two switches.,It's OK.。。 However, if you change to two switches, it may be that the wire in the previous trunking should be lengthened, it is best to buy the same wire extension, and to avoid wire leakage, in case of short circuit, it is best to use adhesive tape with good insulation.

  13. Anonymous users2024-01-12

    Yes, I can change the switch of the light and ventilation fan to a remote control.

Related questions
5 answers2024-08-22

Disassemble the switch to connect the light and see how many wires there are, if there are only two, it means that the wire of the exhaust fan and the wire of the lamp are connected together. There is no other way but to re-run the line from the line pipe. If there are four wires, determine which two are connected to the fan, and then change them to the other switch.

3 answers2024-08-22

It is estimated that it is the winding inductance of the exhaust fan motor, the high-voltage self-inductive electromotive force generated at the moment of the exhaust fan start-up (the principle is introduced in junior high school physics), and the distributed capacitance between the wall switch traces (the capacitance is the path to the AC) is connected into the LED circuit disconnected by the switch, which instantly forms a larger leakage current than that of the non-inductive electrical switch, which causes the LED to drive and start the LED to light up. >>>More

2 answers2024-08-22

This electrician should not be professional enough, the two live wires are connected to the lights and exhaust fans respectively, and the other end is switched, and the two neutral wires are connected.

6 answers2024-08-22

It's okay on one circuit, but don't put it on the same switch to control, turn on each one. So that there will be no problem.

1 answers2024-08-22

If you search on Taobao, you will know that there are many above. It's just that now the bathroom is basically a three-in-one or five-in-one, and it is relatively rare to use a single function, so you can consider it yourself.