Can the check valve completely solve the problem of kitchen flue odor transfer?

Updated on Kitchen 2024-08-24
2 answers
  1. Anonymous users2024-01-24

    1. The auxiliary flue must be retained.

    Each kitchen has a flue, and at the same time, the flue is also divided into main and secondary, the main flue runs through the entire building, and the auxiliary flue is relatively independent. Generally, the oil smoke in the home will first go to the auxiliary flue, and then enter the main flue through the hole in the partition, so as to ensure that the oil smoke of each household is isolated. However, if the secondary flue is directly connected to the main flue, the pressure will be too low, resulting in back-up or cross-smoke.

    Second, pay attention to the construction details.

    First of all, it is important to choose the location where the range hood is installed. The shorter the pipe, the better. Some owners will stretch the pipe longer for the sake of aesthetics, so that after turning off the range hood, a lot of oil smoke will accumulate in the pipe and cannot be discharged, and then poured back indoors.

    In addition, in order not to destroy the original main and auxiliary flues, the opening direction can not be changed at will, and must be played in the auxiliary flue.

    3. Pay attention to safety in window smoke exhaust.

    In order to avoid the problem of string smoke, some owners abandon the original flue and directly open a hole in the window to exhaust smoke, which is okay, but there are a few points to note: first of all, the consent of the property must be obtained before opening a hole in the window or wall; Secondly, pay attention to safety issues, generally the end of the smoke exhaust pipe is made of metal, if the hole is too small, the metal heat transfer may make the glass burst, injuring pedestrians, and the smoke pipe leads to the window, and the strong north wind blowing will cause the smoke to back. It's a good idea to put the pipe out and let it go down, so that it also prevents rainwater from flowing into the pipe when it rains and keeps the wind out.

    Fourth, the check valve is replaced frequently.

    If the auxiliary flue has been removed, or if it is better to prevent the back-up of smoke, then use the flue check valve. Installing a check valve in the flue can protect the range hood so that the smoke in the flue will not back up into the pipe and the range hood. However, after installing the check valve, it should be cleaned regularly, otherwise the check valve will be open and lose its effect, and the flue check valve should be replaced once every two years or so.

  2. Anonymous users2024-01-23

    e68a8462616964757a686964616f31333361306365

    1. The auxiliary flue must be retained.

    Each kitchen has a flue, and at the same time, the flue is also divided into main and secondary, the main flue runs through the entire building, and the auxiliary flue is relatively independent. Generally, the oil smoke in the home will first go to the auxiliary flue, and then enter the main flue through the hole in the partition, so as to ensure that the oil smoke of each household is isolated. However, if the secondary flue is directly connected to the main flue, the pressure will be too low, resulting in back-up or cross-smoke.

    Second, pay attention to the construction details.

    First of all, it is important to choose the location where the range hood is installed. The shorter the pipe, the better. Some owners will stretch the pipe longer for the sake of aesthetics, so that after turning off the range hood, a lot of oil smoke will accumulate in the pipe and cannot be discharged, and then poured back indoors.

    In addition, in order not to destroy the original main and auxiliary flues, the opening direction can not be changed at will, and must be played in the auxiliary flue.

    3. Pay attention to safety in window smoke exhaust.

    In order to avoid the problem of string smoke, some owners abandon the original flue and directly open a hole in the window to exhaust smoke, which is okay, but there are a few points to note: first of all, the consent of the property must be obtained before opening a hole in the window or wall; Secondly, pay attention to safety issues, generally the end of the smoke exhaust pipe is made of metal, if the hole is too small, the metal heat transfer may make the glass burst, injuring pedestrians, and the smoke pipe leads to the window, and the strong north wind blowing will cause the smoke to back. It's a good idea to put the pipe out and let it go down, so that it also prevents rainwater from flowing into the pipe when it rains and keeps the wind out.

    Fourth, the check valve is replaced frequently.

    If the auxiliary flue has been removed, or if it is better to prevent the back-up of smoke, then use the flue check valve. Installing a check valve in the flue can protect the range hood so that the smoke in the flue will not back up into the pipe and the range hood. However, after installing the check valve, it should be cleaned regularly, otherwise the check valve will be open and lose its effect, and the flue check valve should be replaced once every two years or so.

Related questions
1 answers2024-08-24

It is mainly that there will be a thick layer of white foam on the water seal before use, so that there will be no splashing and no smell.

1 answers2024-08-24

In order to ensure the normal operation of the ultra-low temperature freezer and prevent damage to the equipment, it is recommended to pay attention. Home Hygiene Report surveyed on bathroom sealants, refrigerators, kitchen rags. Fruits with skin should be washed thoroughly after being frozen; Fruit without skin.

3 answers2024-08-24

Change to a smoke-free pot, save water, fuel, gas, and can be used for 99 years.

2 answers2024-08-24

Cut off the entrance of flies! Do a good job of kitchen hygiene! I hope it helps.

1 answers2024-08-24

It can't be completely solved. If it is determined that it is not a pipe problem, it can only be said that there is a problem with the original waterproofing layer. Tile joints can only be covered with "cologne" fine seam adhesive. Penetrating crystalline materials cannot compensate for tile joints.