Problems with changing the sewer pipes in the toilet

Updated on Toilets 2024-08-26
3 answers
  1. Anonymous users2024-01-24

    No matter how you change it, you have to dismantle the toilet, and it is recommended to use cement to wrap the leakage point.

  2. Anonymous users2024-01-23

    You can replace one side of your house completely, and you can't hand over an old cast iron pipe and PVC pipe in your own house.

  3. Anonymous users2024-01-22

    1. After the installation of the water pipe, the pressurization test must be carried out: the pressurization test is generally carried out under the condition of double water pressure, and there should be no water leakage in the test.

    2. A simple test method without pressurization, but it is not completely feasible.

    Close the main valve of the water pipe. (i.e. the water pipe switch in front of the water meter).

    Turn on the faucets in the room for 20 minutes, making sure there is no more water and turn off all the faucets.

    Turn off the water inlet switch for equipment with a water storage function, such as toilet tanks and washing machines.

    Open the main valve of the water pipe.

    Check the meter for movement, including slow movement, 20 minutes after opening the main valve. If there is movement, it is a water leak. If you don't move around, you'll probably be fine.

    If there is a problem with the water meter or if the water pipe is slightly percolated, it may be difficult to determine. Therefore, it is recommended that the water pressure test experiment must be carried out after the construction, generally 8 kg, and the time is 20-30 minutes.

    3. Water pipe direction: It is recommended that the water pipe go to the top is the safest. The main reason is that most of the waterway reconstruction is done by dark pipes, and the characteristic of water is that water flows to a lower place.

    If the pipeline goes underground, it is difficult to find the leakage in time once it occurs, and the leakage will only be found if the water overflows or the floor is deformed and leaks downstairs, and it is difficult to find the leakage because the water pipe is buried in the dark. At this time, the huge loss is irreparable, and even seriously affects the friendly neighborly relationship; If the water pipes go to the top, it may be more expensive to change the water, but as a long-term investment, it is worth it. Even if the water pipe goes to the top, even if the water leaks, it can be found in time, which is convenient for maintenance and the loss is small.

Related questions
2 answers2024-08-26

1.The toilet at home is very smelly and smelly, and the reason for seeing that there is no water in the urinal pipe may be that the curvature is not enough and there is no water to block the smell coming out of the sewer pipe, and the main sewer pipe at home is pressed in the toilet. Brothers, please. And the professional point to help me think of a way. >>>More

1 answers2024-08-26

The sewer pipe is public, if there is a problem, let the property or the developer take care of it, because it involves multi-floor residents, so it is easy not to do it yourself, so as not to have any responsibility in the end you will be responsible. It is wise to let the property do it, anyway, they are idle and can't waste your property fee in vain.

4 answers2024-08-26

The reason for your toilet leakage is likely to be that the toilet is not installed properly--- the pit injection is not aligned, or there is a situation that the toilet has two puddles Note 30-40, one of which is not used The pit injection is not sealed in the leakage, because the toilet is equipped with a flange, so it can't leak into the sewer pipe, and it overflows. It has nothing to do with the pipeline you talked about.

7 answers2024-08-26

Upstairs and downstairs apportionment should be, because it is used by everyone, oh you close the main gate of the water gate without anything to do, make a fuss, or pile up some sundries at the door of the first floor. Ha, let's negotiate with each other, a harmonious society! >>>More

9 answers2024-08-26

You are wrapping the riser, the riser needs to leave a check port when there is a cleaning port at a one-meter position, and the cleaning port is sparse when the riser is blocked. If you don't have a cleaning port, you don't need to leave it. I don't know if your own kitchen floor has been renovated, if not, it is a problem with the construction unit.