The newly renovated bathroom leaks water under the tiles and flows out of the door, and the repairer

Updated on Bathroom 2024-07-28
5 answers
  1. Anonymous users2024-01-24

    The reasonable process is that the waterproof layer itself should be tilted and diverted to the sewage sewer pipe to open a small hole and discharge. The surface of the tile seeps into the water, or the toilet, washstand, and floor drain have clean sewage seeping into the compacted layer. It can also be completely eliminated to ensure that there is no stagnant water.

    The stagnant water in the bathroom will stink in the future, so be cautious!

    1. General grouts cannot guarantee no water seepage! 2. Tile gaps have the function of seepage under special circumstances! 3. Even if it is pure cement, porosity exists.

    There is no guarantee that the water will not seep! 4. Laying tiles is not for waterproofing with tiles! 5. There is a solution process diagram in mine!

    You can refer to it! Under the tile, no water can be stored. However, the water seepage situation is determined by the material, and it is difficult to achieve the level of anti-seepage materials used in general households.

    Therefore, prevention is not the way, water seeps into the waterproof layer and then diverts to the sewage pipe for discharge!

    According to this process, the floor of the bathroom and kitchen can be guaranteed to be dry and tidy;

    So it's a process problem, not a re-brick that can be solved!

  2. Anonymous users2024-01-23

    No, there should be no water storage under the tiles, indicating that the mortar is not full and the hook joints are not tight when pasting the tiles. In this case, the only way to do this is to uncover the bricks and re-lay them.

  3. Anonymous users2024-01-22

    This is the tile is not paved, it is best to shovel and redo a waterproof to pave it, it is best to do the door stone, otherwise it is easy to stink under the tile for a long time, and the current waterproof is also easy to break!

  4. Anonymous users2024-01-21

    The bathroom is about one centimeter lower than other rooms, and the water can't flow out of the outside, and the water under the bathroom tiles is that the master did not do the secondary seepage prevention according to the requirements when decorating, and it is done by an inexperienced master, which is a quality problem.

  5. Anonymous users2024-01-20

    Do you really have a bit of a headache with this, is the floor of your bathroom higher than the floor outside the door? The floor of the bathroom should be recessed towards the urinal. I persuaded you to fight again.

Related questions
1 answers2024-07-28

If it is determined that the flooding is caused by the water used in the shower, it can be said that the waterproofing is not in place.

2 answers2024-07-28

1: First of all, check whether the leakage is a waterproof problem or a problem with the inlet pipe and drain pipe being damaged. >>>More

4 answers2024-07-28

The water pipes had to be replaced, and the floor tiles had to be knocked out. There is no waterproofing material that can not knock on the floor tiles. >>>More

4 answers2024-07-28

If you don't completely redo the waterproofing, it's unprofessional. When the time comes, it will have to leak

6 answers2024-07-28

After removing the floating ash debris; The construction quality of the screed layer is not good, the ash is exposed, and the crack of the waterproof layer is exposed, if the crack is wide, the width and depth of the crack are not less than 10mm of the trench, and the floor and the wall interface part of the leakage. Generally, the surface layer is removed locally along the cracks, causing sanding, crisp looseness, string leakage, etc., the thickness of the coating film and the waterproof layer is not enough, the coating film construction process is unreasonable, causing shrinkage cracking, etc., and there is multi-point leakage on the floor due to the poor construction quality of the leveling layer, and the original waterproof layer is not firmly bonded.