4 storey villa frame structure load bearing columns The middle of the living room from south to nort

Updated on Living room 2024-05-04
1 answers
  1. Anonymous users2024-01-23

    A little too small, especially the beam on the north side of the living room, according to the use requirements and the span in your figure, it is more appropriate to choose 240 * 450, and the large span of 240 * 600 can basically meet the conditions. The design of the beam in the self-built house is particularly important, it is used to transfer the load of the plate, here it is emphasized that the lower beam must be reinforced, the upper and lower parts must be reasonable and can not be reversed, for the cantilever part of the beam plate upper steel bar and stirrups use to be particularly strengthened, because it is too vague to see the size of the span, so it can not give you verification of how to match the reinforcement, the stirrup spacing should be reasonable and the length value of the stirrups should be paid attention to.

Related questions
3 answers2024-05-04

If the balcony rests on the cantilever beam, the side beam should be set on the outside of the balcony board, and the balcony board transmits the force according to the two-way plate, and part of it is directly transmitted to the cantilever beam, and part is transmitted to the side beam, and then the side beam is transmitted to the cantilever beam. The reinforcement of the balcony slab should also be reinforced in the way of the cantilever slab, that is, the steel bar at the top of the slab should be set up along the length and appropriately strengthened.

1 answers2024-05-04

Single-storey houses with small spans and small bays do not have to be framed structures. It is normal for you to do a frame structure with columns of 300 300, however, you should at least set up a tie beam tie in the direction of the absence of a frame beam. It's a stable structure.

1 answers2024-05-04

Distinguished, the plate structure refers to the front and back of the house structure, the ventilation is better, and the corresponding is the tower structure, and many houses on the first floor are surrounded by a circle. >>>More

1 answers2024-05-04

The landlord's inscription is not clear. Is there a beam?I don't ask about the size of the beam, I don't ask about the longitudinal reinforcement of the beam, but I ask about the stirrup specifications! >>>More

1 answers2024-05-04

Yes, this more than 3,000 square meters needs to be equipped with a fire sprinkler system.