Does the toilet wall of the frame structure house need to be waterproofed?

Updated on Toilets 2024-09-14
5 answers
  1. Anonymous users2024-01-24

    Of course, it needs to be waterproofed again. When the commercial house is handed over, the kitchen and bathroom will be waterproof, and the waterproof height of the wall is generally meter high. However, after receiving the house, the waterproofing will be destroyed when the water and electricity are installed, and the original waterproof layer must be redone no matter how much is damaged.

    The waterproofing of the home decoration wall is generally based on the wall of the bedroom, so as not to seep into the bedroom after a long time. The waterproofing of the kitchen wall is generally higher than the installation height of the water supply pipe.

    Bathroom wall waterproofing treatment method:

    One of the waterproofing treatment methods for bathroom walls: when doing wall waterproofing, the waterproof layer must sit before laying wall tiles. Generally, the wall should be waterproofed with a height of 30 cm in the wall waterproofing treatment, but for non-load-bearing light walls, the entire wall should be waterproofed, at least 60 cm high.

    One of the waterproofing treatment methods for bathroom walls: when doing wall waterproofing, the waterproof layer must sit before laying wall tiles. Generally, the wall should be waterproofed with a height of 30 cm in the wall waterproofing treatment, but for non-load-bearing light walls, the entire wall should be waterproofed, at least 60 cm high.

    Bathroom wall waterproof treatment method three: the owner had better ask the decoration team to do a good job of cement mulch for the upper and lower water pipes of the bathroom, brush 10 20 cm of waterproof paint from the ground, and then redo the ground ester waterproofing, plus the original waterproof layer, form a composite waterproof layer, in order to enhance waterproofness.

    Bathroom wall waterproof treatment method four: the wall water pipe groove should also be waterproof, in the construction process in the pipe, floor drain and other through the floor, the waterproof layer around the hole must be carefully constructed. Buried water pipes in the wall, so as to achieve a reasonable layout, lay water pipes are made of grooves larger than the pipe diameter, plastering in the groove is smooth, and then brush waterproof paint in the groove.

    Bathroom wall waterproofing treatment method five: in some special positions, such as the shower position adjacent to the wall waterproofing should be at least meters high. If the bathroom has a bathtub, the height of the waterproofing paint on the wall adjacent to the bathtub should also be higher than the upper edge of the bathtub.

    Bathroom wall waterproof treatment method six: the wall treatment is clean and flat, no floating ash, small particles, and the junction of the wall and ground is wiped with small original corners or slope corners. When brushing waterproof coating, paste 1 2 layers of glass wire cloth reinforcement.

    The total thickness of the polyurethane waterproof coating film is required to be more than millimeters. It can't be decided by the number of passes. The pipe root and the corner of the reinforcing layer are brushed first, and after the surface is dried at room temperature for 4h, then a large area is brushed and scraped.

    There shall be no leakage and bubbling. Brush a large area for 24 hours and then apply the next layer after curing.

  2. Anonymous users2024-01-23

    Of course you need it, waterproofing has nothing to do with the structure of the house.

  3. Anonymous users2024-01-22

    It must be done to spray the wall with waterproofing, and it must also be done according to the current regulations.

  4. Anonymous users2024-01-21

    You need to do a little bit from the ground, not all of them.

  5. Anonymous users2024-01-20

    The ground tarp is back 250mm

Related questions
1 answers2024-09-14

In general, there are no other concrete components on the outer wall of the frame structure except for the frame column and the frame beam, and when the net height of the wall is greater than 3 meters and the net length of the filling wall is more than 5 meters, a ring beam or structural column is generally added in the middle.

2 answers2024-09-14

This is often the case when renovating, and it is not surprising that the building will not be affected. Now if you want to repair it, you just need to paint it flat with cement mortar.

3 answers2024-09-14

No, you should figure out that the graduation project when you were a student is purely for the purpose of exercising your hand arithmetic skills, and it will not create something very high. Simplify what can be simplified, don't dwell on it so much.

1 answers2024-09-14

You bury that water pipe in the wall, and change the faucet, which is the water valve you said, which can be buried in the wall.

1 answers2024-09-14

Single-storey houses with small spans and small bays do not have to be framed structures. It is normal for you to do a frame structure with columns of 300 300, however, you should at least set up a tie beam tie in the direction of the absence of a frame beam. It's a stable structure.