How to lay electric floor heating in the bathroom is safer

Updated on Bathroom 2024-08-26
1 answers
  1. Anonymous users2024-01-24

    First of all, before and after the installation of electric floor heating, waterproofing should be done once (twice in total). There are also two isolation layers in the upper part of the filling layer of the bathroom. Isolate water from underfloor heating; The quality of waterproof materials should be qualified, flexible materials should be selected, and the construction technology should be absolutely excellent; If it is a non-load-bearing lightweight wall, the whole wall should be waterproof, and the wall with shower facilities should be meters high.

    Secondly, a waterproof wall needs to be set up at the entrance of the bathroom, and cooperate with the civil engineering unit to do waterproofing on the inside of the professional waterproof wall to prevent stagnant water from seeping into the insulation layer.

    In addition, the spacing of heating cables should not be less than 5CM, and when the cables are laid, they should be close to toilets, baths, washbasins and other sanitary ware, and a certain distance should be left.

    People in the electric floor heating industry generally raise doubts about the first two points. Some professionals believe that even if two layers of waterproofing are made, the moisture cannot be stopped, and the insulation resistance will drop significantly, and it will not be able to push it up when it is empty. In addition, in a humid environment, the requirements for external joints are very high, and there must be no gaps.

    Therefore, this is not a waterproof solution, and the reason needs to be found from the cable itself. Like electric heating film, carbon crystal floor heating, including some carbon cables and carbon fiber cables on the market in the past two years, they must not be laid in the bathroom, because there are different defects in their materials, production processes and construction processes. If the bathroom is to be laid with floor heating, it is recommended to use a high level of heating cable, especially the heating cable produced in Europe, the production process is completely in accordance with the European IEC800, VDE standard production, its safety level is used in the wet area like the toilet or even more harsh environment can also be said to have no hidden dangers!

Related questions
5 answers2024-08-26

Although the bathroom often uses water, there will be a dampness problem. But now the electric floor heating technology has been very mature, its own insulation structure is quite safe, insulation and waterproofness have their test report, in the installation combined with leakage protection and intelligent control system, can effectively ensure the safe operation of electric floor heating in the kitchen, bathroom and other humid environments. If it is a regular, quality-assured floor heating company, it must be relatively safe. >>>More

2 answers2024-08-26

Safe. Although the kitchen and bathroom will be water or wet, the insulation structure of the electric floor heating itself is quite safe, and the insulation and waterproofness have their test reports. First pasture floor heating, escort for you.

2 answers2024-08-26

No, small seams are paved and sewn with clean ash.

4 answers2024-08-26

Not recommended.

If your bathroom is big enough to separate wet and dry, that's fine; >>>More

1 answers2024-08-26

The bathroom area is relatively small, and the installation of electric floor heating is actually not very energy-saving, and this place is not a living area, so it is not power-saving.