The balcony is 2 5 meters outside, the beam width is 0 3 meters, the beam height is 0 55, and the be

Updated on Balcony 2024-07-03
2 answers
  1. Anonymous users2024-01-24

    To answer that the height of the beam is too small, there are some problems in this design, it is recommended to increase the beam height and width ratio, the main reinforcement of the cast-in-place cantilever beam is 25mm rebar, and the negative reinforcement is not less than 16mm rebar, the cantilever (extension) is generally not more than 150 cm, the beam height (including the height of the plane part) is 40 cm, and the bottom width is equal to the thickness of the wall; The arc part is made of 16mm rebar, the top and bottom are the same, the height is the same as the cantilever beam, and the width of its bottom surface is 15 16 cm; The rear body of the cantilever beam is connected with the ring beam, and the total length of the cantilever beam part is about 4 meters; The reinforcing bars of the flat part of the balcony are arranged in a criss-cross manner, and are inserted into the cantilever beam, the arc beam and the ring beam inside. If it is an overall cast-in-place floor, the reinforcement is also better to consider the overall layout.

  2. Anonymous users2024-01-23

    The height of the beam is too small, it is recommended to increase the beam height.

Related questions
2 answers2024-07-03

The balcony beam slab is an integral cast-in-situ or a prefabricated slab on the beam, because the balcony beam slab is an integral cast-in-situ force in the short side direction, and the prefabricated slab on the beam is stressed in the long side direction. The calculation method of the structure is different depending on the direction of the force. Please add clarity.

4 answers2024-07-03

1. This balcony of all landlords can only be a general leisure balcony, and the bearing capacity is estimated to be around 100 kilograms per square meter. >>>More

1 answers2024-07-03

Safe. Cantilever balcony, 1800mm outside, 4200mm wide, one beam on each side, and the beam can be pressed to do >>>More

2 answers2024-07-03

I hope to change the design, but if you want to do it, you need to use cement above C40, and increase the height-width ratio of the beam

1 answers2024-07-03

The protruding pick is OK The pile is very good with 6 16 (for the consideration of adding layers in the future) Since the column is a structural column, 4 14 are on the line of the beam, and the bottom three 16 are on the top two with 14 The beam should be reinforced!