How to do grounding of the KBG pipe inside the wall base of the ceiling? How do I jump over a ground

Updated on Suspended ceilings 2024-07-02
1 answers
  1. Anonymous users2024-01-24

    K-crimp connection.

    B - Thin-walled. G-Steel Pipe.

    KBG pipe should refer to the use of socket crimping connection technology, instead of the traditional glue connection or welding construction, and no need to do jumper wires, not a certain brand, KBG pipe is a material model, and SC, G pipe. It's just that the pipe wall is a little thinner. It is a threading pipe, which is generally used in the underground layer, and his price is a little cheaper than that of SC pipe, which is different from the appearance, with a layer of glaze-like plating!

    KBG steel conduit is precision machined and chrome-plated on both sides, which is both beautiful and has good anti-corrosion performance.

    There is no need for welding machines and threading equipment, nor do you need to do cross-grounding wires, and there is no need to paint, which eliminates the need for complex construction processes such as traditional fusion welding and threading. Just connect the straight pipe with a joint to the pipe, connect the pipe with the threaded box joint with the junction box, and tighten it with a set screw after positioning.

    If there are special provisions in the design, you can use pipe clamps to connect both sides of the pipe joint, and then connect them with multiple strands of copper bare wires on the small bolts of the pipe clamps on both sides.

Related questions
2 answers2024-07-02

The most used is the T4 lamp, which looks like a small fluorescent lamp, and the better quality is T5 >>>More

2 answers2024-07-02

For ceiling panels, to wipe the fumes regularly, you can moisten the rag to wipe gently, and then wipe again with a dry rag. >>>More

3 answers2024-07-02

Remove, wash and reattach.

3 answers2024-07-02

In order to ensure safety and keep the line out of chaos, it is best to carry out casing, otherwise there may be problems in the future line management or old replacement of the wire skin. >>>More

1 answers2024-07-02

It shows that a wet or poor quality wooden keel was used at that time. At present, the decision is made on a case-by-case basis - if the area is large, it must be redone; If it can be repaired, it should be repaired in advance.