40 square meters of living room and dining room, is it enough to use 2 horses?

Updated on Living room 2024-06-25
4 answers
  1. Anonymous users2024-01-24

    Enough The living room at home is more than 50 square meters, with 3 horses, sometimes it's so cold in summer... It is recommended that 2 horses is enough and does not waste electricity

  2. Anonymous users2024-01-23

    2 horses are insufficient, the machine is small and the machine is tired, it is recommended to work with the machine.

  3. Anonymous users2024-01-22

    It depends on how your glass windows are, preferably 3P, with a larger point than not enough.

  4. Anonymous users2024-01-21

    40 square meters of area suitable for the use of air conditioning: hp - 3 hp; 2 horses are not enough.

    Air conditioning with area calculation:

    Air conditioners need 150W of cooling capacity per square meter: thus introducing the calculation formula for using air conditioners in the room area:

    Cooling capacity 150W= 2= 2=0" "That is, the area that adapts to the room" "0" is to adapt to the maximum area, "0" is to adapt to the minimum area, for example: KFR-2601GW BP Cooling capacity: 2600W2600 150=17 17+2=19 17-2-15, that is, the applicable area of the air conditioner is:

    15-19 , the number of horsepower of the air conditioner also comes from this.

    Air conditioner applicable area:

    1P:11-17㎡ :18-25㎡ 2P:30-33㎡ :18-23㎡

    3P: 40-45 5P: 60 or so 10P: 50 or so.

Related questions
6 answers2024-06-25

Not enough. Generally, the household air conditioner is configured according to the cooling capacity of 160 220W square meters. According to this calculation, the total cooling capacity required for a 40-square-meter room is 6400 8800W, with an average value of 7600W. >>>More

1 answers2024-06-25

Large 3 hp or 4 hp air conditioning.

The number of air conditioners in the family living room is generally configured according to the actual usable area of the room with a nominal cooling capacity of 160 220W square meters, which varies depending on the heat preservation state of the room, the orientation of the room, and the amount of heating equipment in the room. >>>More

3 answers2024-06-25

Generally speaking, household machines need about 200W per square meter, and take your 44 square meters that requires 8800W output power, and there is no door in your balcony, only curtains, and the cold and heat radiation is relatively large, so it is more suitable at 9000W. But there is no 9000W machine at present, so I suggest that in order to better refrigeration and heating effect, it is recommended to equip a cabinet with 3P, the output power of 3P is 7500W, according to what you said, it is not enough for the balcony. >>>More

4 answers2024-06-25

Horsepower refers to the power consumption of electrical appliances, 1 horsepower = 1 horsepower = 735W, horsepower does not refer to cooling capacity. Usually how many horsepower of the air conditioner is estimated, the cooling capacity of the air conditioner is estimated according to the power consumption of the air conditioner. >>>More

1 answers2024-06-25

Inadequate. Under normal circumstances, the heating capacity of the air conditioner is about 4000W, and under normal circumstances, the configuration per square meter is about 200W, so the applicable area of heating is about 16 square meters. >>>More