Kitchen living room wires are used 2 5 square or 4 square

Updated on Kitchen 2024-05-15
5 answers
  1. Anonymous users2024-01-23

    Yes, the kitchen is good to do 4 square lines. Even if you don't use electrical appliances now, you may use them later, which is called taking precautions. If you use a flat wire, you can't use it if you want to use it in the later stage.

    Just like floor heating, many people will start to say that floor heating may not be needed in winter, and there is no floor heating if you want to use floor heating in winter.

  2. Anonymous users2024-01-22

    The recommended current carrying capacity of 4mm2 is 30A, and the power is 5KW

    One induction cooker 2KW

    One rice cooker 1KW

    There are other appliances as well.

  3. Anonymous users2024-01-21

    The general air conditioner is 4 square meters, and there is no problem with the wattage bottom square of kitchen and living room appliances, unless you have special appliances. But it's nothing to change to 4 squares.

  4. Anonymous users2024-01-20

    Kitchen and living room wires should be laid according to the installation capacity, and the maximum load of each branch should not exceed 15 amps.

    For example: * square millimeter copper core wire open-wire device safety carrying capacity is 28 amps; If it is two wires through the steel pipe, the safe current carrying capacity is 23 amps; If it is three wires through the steel pipe, the safe current carrying capacity is 21 amps;

    The safe ampacity of the 4 square millimeter copper core open-wire device is 37 amps; If it is two wires through the steel pipe, the safe current carrying capacity is 30 ampere; If it is three wires through the steel pipe, the safe current carrying capacity is 27 amps;

  5. Anonymous users2024-01-19

    If you use a high-power electrical appliance, it is easy to overheat and soften if it is low.

Related questions
1 answers2024-05-15

Is the specification of the kitchen wire square or square? Common sense of life, household appliances. According to your description, you need to use 4 square millimeters for electricity in the kitchen, 6 square millimeters for the home bus, and only the light line in the home can use square millimeters. The minimum socket is 4 square millimeters.

6 answers2024-05-15

Most people in Big Oak will be extremely entangled in this problem before renovation. In my opinion, if you are renting a house and don't use many electrical appliances, you can consider it, but if it is used by a family, there is an induction cooker, a range smoke, a microwave oven, and a rice cooker, it should not be enough. It would be a bit dangerous in case all the appliances were turned on together. >>>More

1 answers2024-05-15

6 or 10 square copper wires for entrance lines, 4 square copper wires for kitchens, 4 square copper wires for bathroom sockets, 4 or 6 square copper wires for electric hot water, 4 square copper wires for air conditioners, square copper wires for lighting circuits, square copper wires for living room and bedroom sockets.

1 answers2024-05-15

No problem.

Copper wire, no more than 3A current per square millimeter. >>>More

4 answers2024-05-15

There is no need to worry about this, in fact, the square wires are enough. But in our decoration, for the sake of insurance, we generally use 4 square wires for kitchen sockets. It's really safer to do this, and there is no psychological entanglement. >>>More