If the fire sprinkler pipe is in the ceiling, it does not need to be painted.

Updated on Suspended ceilings 2024-04-28
7 answers
  1. Anonymous users2024-01-23

    Regardless of whether it is in the ceiling or not, the fire hydrant system generally uses welded steel pipes, and the surface needs to be anti-corrosion, and at the same time, there must be color marking, so all are generally painted with red paint; One anti-rust paint, 2 red topcoats;

    The spray system is generally made of hot-dip galvanized steel pipe, which is connected by grooves, so it generally does not need to be painted, and only serves as a functional identification of the pipeline.

  2. Anonymous users2024-01-22

    This design does not require a drawing brush, just do the pipe color ring.

  3. Anonymous users2024-01-21

    No, Article 1 of the Technical Specification for Fire Water Supply and Fire Hydrant Systems (GB50974-2014).

  4. Anonymous users2024-01-20

    If it is a galvanized pipe, you don't need to brush it, it is generally galvanized.

    There should be no need to paint.

  5. Anonymous users2024-01-19

    It is best to brush down the anti-rust paint, brush it when the fire pipe is installed, rarely do not see the brush, do not brush will rust, the regulations do not see,

  6. Anonymous users2024-01-18

    Generally, it is painted with ordinary iron red paint.

  7. Anonymous users2024-01-17

    Anti-rust twice on the red side.

    You can check the construction specifications and drawing instructions.

Related questions
4 answers2024-04-28

The ceiling in the living room is generally just a walk, so there must be a ceiling on the side of the door, if you feel uncoordinated, you can consider adding a beam, otherwise you don't need to.

10 answers2024-04-28

According to Article 23 of the Law on the Protection of Consumer Rights and Interests, consumers can request a return or exchange of goods in question, and in this case, consumers can negotiate with the restaurant to either return the dish or change another dish, because this is caused by the restaurant's work error, and if the restaurant has committed fraud, the consumer can claim double the amount of compensation. >>>More

1 answers2024-04-28

From the point of view of decoration, there is no problem with sealing the fire sprinkler with the ceiling, and it is more beautiful. >>>More

1 answers2024-04-28

Know when the gas is off, and if it doesn't interfere with lunchtime, use electricity for cooking and boiling water to prepare. Kitchen materials are prepared normally. >>>More

1 answers2024-04-28

If the guest can accept it, it will be half price, and if the guest really doesn't like it, it can only be used as the price of punishment for mistakes.