The 4 square lines of the home decoration have a single toilet gate box, and the external meter 100A

Updated on Toilets 2024-04-23
3 answers
  1. Anonymous users2024-01-23

    No. The 4 square power cord of the cloth during home decoration is through the pipe and embedded in the wall, and the safest carrying current value of the power cord of this specification in this state is about 23A, that is to say, the maximum bearing power is that the power of the instantaneous electric water heater is too large, at least 6 square meters of national standard copper core wire should be used.

  2. Anonymous users2024-01-22

    8500 watts of water heater, the main line should use 6-10 square copper core wire, the entrance line should use 10-16 square copper core wire, 4 square copper core wire, the maximum power of the open line can only withstand 7200 watts, but now it is all dark line laying, can only withstand 5500 watts of electrical power, so the use of this instantaneous electric water heater is not good, if you want to use it must be re-routed.

  3. Anonymous users2024-01-21

    This capacity can be installed in an instantaneous electric water heater.

Related questions
1 answers2024-04-23

Is it okay to have a 4 square copper wire for home improvement open line? 】 >>>More

6 answers2024-04-23

At 220 volts, each kilowatt of current is amperes.

For square copper wires, the safe current density should not exceed 4 amperes per square. Squared, the allowable safe current is ampere. It is equivalent to having a safe power supply capacity of kilowatts. >>>More

1 answers2024-04-23

If the economy allows, it is recommended to change it, because now most people will add new kitchenware at home, and if you want to use more electricity in the oven and microwave oven, you are afraid that it will not be able to drag it or it will be easy to short circuit for a long time.

4 answers2024-04-23

Obviously it is not enough, the electricity consumption between the kitchen and bathroom is very large, since the line is not easy to change now, then you should pay attention to the high-power electricity when you use electricity do not open at the same time, and it is best to replace it with 4mm2 when there are conditions in the future.

3 answers2024-04-23

Yes, it is necessary to open the empty open at any time.

When 3P air conditioning also needs more than 2000W of power for heating, it is estimated that the power of electric heating can reach 3500-4000W, so that the current can reach about 15-20A. >>>More