Is there a distance between the balcony floor drain and the sewer pipe, will the water leak into the

Updated on Balcony 2024-04-22
1 answers
  1. Anonymous users2024-01-23

    It can only be said that there is such a possibility.

    There is a certain distance between the floor drain and the sewer pipe, if the floor drain has a large amount of water leakage for a long time, the water will slowly seep into the wall along the empty distance in the middle, and some other troubles will occur after a long time.

    It is recommended to consider properly waterproofing the area between the sewer nozzle and the floor drain or adding a section of water pipe with a larger pipe diameter, and stuffing glue in the gaps.

Related questions
6 answers2024-04-22

The upstairs is right, you have to negotiate with the upstairs before dealing with it. It needs to be added that the sewer pipe is connected to the main pipeline for sewerage, and this part should be dealt with. Just in case.

3 answers2024-04-22

In this case, it is recommended to take out the floor drain, fill the gap with water without leakage, and then install the floor drain, do not let the water not leak into the sewer pipe or block the floor drain drain, and then do a good job of waterproofing the edge of the floor drain.

1 answers2024-04-22

The balcony is generally installed with rainwater pipes, and there is generally a floor drain on each floor, and the inspection port (sweeping port) is no longer installed in other locations, because the drainage outlet on the top floor is also a floor drain, and the floor drain itself is buckled, and the rainwater is not too dirty and seasonal drainage, so the sweeping mouth is generally not installed

2 answers2024-04-22

You can only negotiate with the property, this should be the upstairs waterproofing treatment is not good, resulting in the waterproof layer and the ground water storage, and then slowly leaking to your home. This is because it is a new house, and after you look for a property, the property will contact the developer. When dealing with it, remember that the waterproof layer upstairs can not be immediately constructed after the waterproof layer is dug upstairs, and then re-lay the waterproof layer after the ground is completely dry upstairs, in addition to the floor drain upstairs, wall pipes and other parts are recommended not to use membranes, the use of polyurethane will be a little better, but the smell will be very large, it is estimated that the property will use waterproof materials such as polypropylene if repaired, but to do a good job, the construction quality requirements are higher! >>>More

3 answers2024-04-22

Hello, the water has not been dry, you have to pay attention to whether there is still water on it, quickly clean up the water, wait a few days and then observe, if there is still water seepage, explain where there are loopholes in the pipeline, find out the problem in time to fill the leakage, I wish you a happy life!