The heating in my house is finished, but the living room may be too far away, it may not be hot, do

Updated on Living room 2024-04-26
5 answers
  1. Anonymous users2024-01-23

    1 The number of pieces of heating in the living room is too much, as you can see from the floor plan you draw, the heating pipe in the living room is also relatively long, if the inlet and outlet water is on one side, the water circulation is slow, and the heat will be slower.

    2 Without affecting the normal temperature of the rest of the heating, you can turn off the water supply and return valves of the hotter heater, and force the heating in the living room to increase the circulation of water, and the temperature of the living room heating should be improved.

  2. Anonymous users2024-01-22

    Due to the long pipeline in the living room, the resistance of that road is large, and when the water is left there, most of the water flows away from the main pipe with low resistance, resulting in a short circuit in the living room heating. Installing a door on the main pipe of the living room radiator increases the resistance of the main pipe, so that the hot water is diverted into the living room heating pipe, but this will make the temperature of the radiator connected after the living room heating drop.

  3. Anonymous users2024-01-21

    The main pipe of the living room radiator is equipped with a broken door, and at the same time to ensure the indoor sealing, which is the primary condition to ensure the indoor temperature.

  4. Anonymous users2024-01-20

    1. First of all, deflate the air (radiators at home and outdoor heating pipes) to ensure that there is no air in the heating;

    2. There are two control valves for a group of heating, mobilize the valve, look at your indoor heating pipe, the nearest from the outdoor heating pipe should be adjusted smaller, and the nearest from the outdoor heating pipe should be adjusted to the maximum.

  5. Anonymous users2024-01-19

    Without affecting the normal temperature of the rest of the heating, you can turn off the water supply and return valves of the hotter heater to force the heating that is not hot in the living room to increase the circulation of water, and the temperature of the living room heating should be improved.

Related questions
2 answers2024-04-26

The decoration of the home is almost completed, and the decoration plan for the living room has not yet come out? >>>More

2 answers2024-04-26

I don't know if you want to beautify your home through green plants or want to remove indoor pollution through green plants? >>>More

3 answers2024-04-26

Normally, you should be compensated for your loss, and the property heating department and the owner should bear the loss, but in most cases, they don't care at all, they bear it themselves, and you need to have enough time and patience to solve it.

4 answers2024-04-26

It doesn't have to be your home, there is a problem with the waterproofing upstairs, you have to check, whose house is leaking, hurry up and find the developer, the house warranty is limited, and after that, whose house will be repaired. Compensation for the following losses.

1 answers2024-04-26

The water flow is unevenly distributed, turn the living room off a little.