Floor heating water divider: that is the living room, which is the bedroom divider

Updated on Living room 2024-04-28
5 answers
  1. Anonymous users2024-01-23

    Ask the construction company, or have drawings?

  2. Anonymous users2024-01-22

    If you want to use a water separator, it should be the main gate! It's not in the bedroom!

  3. Anonymous users2024-01-21

    Then you have to see how the water pipes go, if it doesn't work, try them one by one.

  4. Anonymous users2024-01-20

    Principle of underfloor heating water separator.

    When the heat medium flows into the room, it enters the main bar of the water separator after the multi-function filter, and the filter filters out the impurities in the heat medium to prevent the impurities from entering the underground pipe network to block the pipeline. The main bar is installed horizontally, so that the heat medium is evenly distributed to the branch pipes by using the principle of equal pressure at the same height, and after the heat exchange system, each branch pipeline flows back to the main bar for water collection, and then flows into the heating system from the return port. In addition, there is a water mixing device in the self-heating, that is to say, after the heat exchange, the temperature of the heat medium (water) is still very high, and after the water mixing system, it flows into the main bar of the water separator to continue circulation, so that energy can be saved while heating.

    Tips for using underfloor heating water separators.

    1. The floor heating water separator can control the heating temperature of each room or area in a separate way, and the user can adjust the temperature of the room according to his own needs; The manual exhaust valve of the water separator allows the user to discharge the gas in the pipeline by himself to ensure the heating temperature of each pipeline.

    2. There is a filter on the front end of the water separator, and the user regularly or irregularly removes the filter screen at the lower end of the filter during the annual heating period to clean and install it to ensure the cleanliness of the water pipe. After the heating is over, the pipe network should be flushed with clean water.

    3. At the beginning of heating, the temperature will not be felt immediately, during which the indoor ground concrete layer is gradually heated, and the heat energy is stored, and the design temperature can be reached after 2-4 days. If the user heats himself, the water temperature should not exceed 65.

  5. Anonymous users2024-01-19

    The house type and the location of the water separator are sent.

Related questions
2 answers2024-04-28

You can try to use some tools to twist it, and normally, the feng shui qi is not easy to break.

2 answers2024-04-28

One thing to pay attention to is that the pipe out of the water separator should be insulated about one meter and a half to prevent the cracking of the tiles caused by the high local temperature.

2 answers2024-04-28

Yes, as long as the water separator is installed, it will not break.

1 answers2024-04-28

The principle of installation that is generally in the bathroom is to press the nearest place where the main water is returned, and it is likely that your main water is given, and the water return is not in the bathroom, which may also cause the bathroom but the pipeline is long, which affects the heating.

6 answers2024-04-28

The floor heating water separator is placed in the cabinet, which will not deform the cabinet surface, but it is very inconvenient to repair, in case the cabinet will be damaged if it leaks.