After the renovation of the home bathroom, the toilet needs to be moved by more than 1 meter, how to

Updated on Bathroom 2024-04-10
10 answers
  1. Anonymous users2024-01-23

    The toilet drain mouth cannot be changed unless it is absolutely necessary, and if it has to be changed, it should be paid attention to:

    1. The interface adopts a 110 necked 90-degree elbow (try to do it down), the horizontal pipe of 110 should be as steep as possible, and a small short pipe of about 30MM should be connected to the 90-degree elbow at the new position;

    2. Use the standard (domestic brand toilet, with a protruding mouth at the drain port, and insert this mouth into the 30MM small short pipe during installation) toilet, do not use double drainage eyes, and pay attention to the use of the toilet.

  2. Anonymous users2024-01-22

    meters, the displacement distance is relatively large, with 75 and 90 pipes, the risk of blockage is too great.

    2.If the 110 pipe is moved, the ground elevation should be about 20 cm if the drop and slope are required.

    3.The better way is to cut the riser, connect the tee, and then the horizontal pipe comes over, install the concealed water tank and the wall-hung toilet, the wall-hung toilet sewage outlet is 23 cm away from the finished surface, the drop is enough, and there is no problem with the sewer. And you don't have to raise the ground. The disadvantage is that the cost is relatively large.

    The renovation of old houses, another name is the renovation of old houses. It generally refers to the renovation and decoration of the decoration style, water and electricity results, kitchen and bathroom department and other redesigns of the house due to the relatively long living time or the decoration does not meet the current living needs.

  3. Anonymous users2024-01-21

    The correct answer is that you can't change the toilet drain of 110 unless you have to, and let's introduce it in detail

    1. If you have to change it, you should pay attention to:

    The interface adopts a 110 necked 90-degree elbow (try to do it down), the horizontal pipe of 110 is as steep as possible, and a small short pipe of about 30MM should be connected to the 90-degree elbow at the new position;

    2. Use the standard (domestic brand toilet, with a protruding mouth at the drain port, and insert this mouth into the 30MM small short pipe during installation) toilet, do not use double drainage eyes, and pay attention to the use of the toilet.

    Expand Exhibition Materials:

    Toilet is a combination of toilet, toilet, and bath. Residential bathrooms are generally divided into dedicated and communal. The dedicated one serves only the master bedroom; The common ones are connected to the public walkways and are shared by other family members and guests.

    According to the layout, it can be divided into three types: independent, dual-purpose and eclectic. According to the form, it can be divided into semi-open, open and closed. At present, it is more popular to distinguish between dry and wet partitions.

  4. Anonymous users2024-01-20

    The principle is that the toilet drain mouth of 110 cannot be changed unless absolutely necessary.

    If you have to change it, you should pay attention

    The interface adopts a 110 necked 90-degree elbow (try to do it down), the horizontal pipe of 110 is as steep as possible, and a small short pipe of about 30MM should be connected to the 90-degree elbow at the new position;

    Use a standard (domestic brand toilet, with a protruding mouth at the drain outlet, and insert this mouth into a 30mm small short pipe when installing) toilet, not double drain eyes.

    Pay attention to the use of the toilet bowl.

  5. Anonymous users2024-01-19

    Rerouting with a 75 pipe just needs to be raised by 150mm

  6. Anonymous users2024-01-18

    Do you move out, or do you lean against a wall?

    Two ways! 1 Ground elevation.

    2 is to choose a toilet with a large drop.

    3 Go straight to the building materials market to see if there is a suitable toilet or ask the owner directly!

  7. Anonymous users2024-01-17

    The toilet needs to be moved in the home improvement bathroom, which can be avoided and best avoided to avoid the toilet blockage in the future; If it is really necessary to change, it is recommended that the bottom pipeline should not be remodeled at a right angle, but must be diagonal, which can minimize the probability of pipe blockage.

    At the same time, when using it in the later stage, we must pay attention not to throw diapers, broken rags and other DD in the toilet!

  8. Anonymous users2024-01-16

    It's best to dig up the heavy security, and if you do a raise, maybe the bathroom is higher than the outside.

  9. Anonymous users2024-01-15

    1. The interface adopts a 110 necked 90-degree elbow (try to do it down), the horizontal pipe of 110 should be as steep as possible, and a small short pipe of about 30MM should be connected to the 90-degree elbow at the new position;

    2. Use the standard (domestic brand toilet, with a protruding mouth at the drain port, and insert this mouth into the 30MM small short pipe during installation) toilet, do not use double drainage eyes, and pay attention to the use of the toilet.

  10. Anonymous users2024-01-14

    1.Expand restroom space: If the restroom is large enough, consider removing or moving the restroom walls to expand the restroom space to accommodate the new restroom location.

    2.Replace the toilet model: If the restroom space does not allow for expansion, consider changing the toilet model and choosing a smaller toilet to accommodate the new location.

    3.Build partitions: Partitions can be built in the bathroom to isolate the toilet bowl so that it does not affect the overall layout of the bathroom.

    4.Build a baffle: You can build a baffle inside the restroom to isolate the toilet from the rest of the area without affecting the overall layout of the restroom.

    5.Redesign your restroom: If none of the above solves the problem, consider redesigning your restroom to accommodate the new toilet location.

    This may require replanning the layout and design of the restroom to ensure the overall aesthetics and functionality of the restroom.

Related questions
2 answers2024-04-10

As long as his home is waterproof in place, there are almost no hidden dangers. In addition, you can ask him to insulate the sewer pipes of his house, which can properly eliminate noise and prevent condensation from forming.

9 answers2024-04-10

If it is on the first floor, the downstairs can not be raised, the pipe can be changed under the ground, and the upstairs should be shifted The toilet should be raised by 15CM to 20CM, and the squatting pit is 28CM to 30CM.

1 answers2024-04-10

In addition to considering the blockage problem, it is also necessary to pay attention to the tightness of the pipe. This is a repeated reminder from experts to the owners, especially the interface position between different pipes, to check whether there are leaks many times, to ensure that there is no leakage, sealing rings, glass glue and so on.