What should I do if I am worried about the leakage of the smart toilet

Updated on Toilet 2024-04-26
9 answers
  1. Anonymous users2024-01-23

    1. Don't be cheap.

    Look for the industry leader who specializes in smart toilet seats, and big brands have strict requirements for quality control. And be sure to buy three plugs, two plugs must not have ground protection.

    2.Look at the test report.

    When purchasing a product, the merchant should be asked to present a test report issued by a third-party organization. This report is generally attached to the product manual, showing twenty or thirty test results in the form of a table, do not buy if there is no report.

    3.Look at the sign information.

    When purchasing, you should pay attention to the quality inspection mark information of the smart toilet seat, and the waterproof level of the product should reach at least IPX4 (splash-proof type), so as to effectively prevent the occurrence of accidents such as short circuit and leakage of electrical appliances caused by water splashing.

    4.Confirm leakage protection.

    When purchasing, it is also necessary to pay attention to whether the product is equipped with multiple anti-leakage protection devices, such as automatic power-off for water heating, automatic power-off protection for seat heating, and automatic power-off protection for warm air drying. It's best to equip it with an independent leakage protection socket and press it often to ensure safety!

  2. Anonymous users2024-01-22

    Can toilet failure analysis and solution:

    1) Fault phenomenon: leakage alarm (buzzer continuous calling, low light continuous flashing).

    Inspection part: (water tank, computer board, strong electrical connection, leaky plug, leaking cleaner).

    Exclusion method: first see if there is a water leakage, if it is solved, if it is not unplugged, the heating line of the water tank is re-opened, if it is normal, the insulation of the heating pipe of the water tank is not good, if the fault is still the same, the computer class is broken, if the leakage alarm is suddenly stopped during the water spraying process, if it is not a water leakage, then adjust the installation strip.

    2) Fault phenomenon: the water discharge motor does not return to zero alarm (5 calls every 3 seconds, and the low light flashes 5 times).

    Inspection part: (drain motor, computer board, hall board).

    Exclusion method: first look at whether the magnet on the cam corresponds to the hall, if it does not correspond to the measurement of the pump of the water discharge motor whether there is a DC 12V voltage, if there is a motor is bad, if there is none, the computer board is broken, if the motor has been rotating, then detect both ends of the hall plate line to see if it is normal, if there has been a 5V voltage, the hall plate is bad.

    3) Fault phenomenon: no drying (other normal).

    Inspection part: (drying motor, computer board).

    Exclusion method: press the drying button after determining the correct seat, and measure whether the drying motor plug has DC 12V voltage, if there is a bad drying motor, if not, the computer board is broken. (Note: If the production is from January to May 05, the computer board and the drying device will be replaced together).

    4) Fault phenomenon: As long as the buttocks are flushed or the women's special water pump has been working.

    Inspection part: (water pressure, pressurization device, computer board, ceramic inner water pipe, solenoid valve).

    Exclusion method: After determining the correct seat, press the cleaning function, unplug the water pressure switch valve line on the computer board, if the water pump is still working, the computer board is broken, if the water pump stops working, it means that the water pressure is not enough, check the filter screen, check the solenoid valve, if the water pipe is pressurized or broken.

    5) Fault phenomenon: the status indicator is fully lit and does not work.

    Inspection part: (remote control, water discharge motor, hall plate).

    Exclusion method: First of all, see whether the remote control is automatically drained to see if it is turned on, and then switch it again to see if the status indicator lights up.

  3. Anonymous users2024-01-21

    The brand's smart toilets have anti-leakage protection devices and flame retardant materials, and the current anti-leakage technology is very mature, so it is impossible to make such low-level mistakes.

    In case of leakage, the main switch will be disconnected directly.

  4. Anonymous users2024-01-20

    As long as you choose a reliable quality manufacturer, it's fine, I use GENOK's, and they have a leakage protection function that I like very much.

  5. Anonymous users2024-01-19

    Smart toilets generally do not leak electricity and are very safe.

  6. Anonymous users2024-01-18

    There will be no leakage, this worry is superfluous, smart toilets have been developed for many years, and the technology has been super mature! There will be no leakage, you can use it with confidence!

  7. Anonymous users2024-01-17

    Smart toilets involve both waterways and circuits, so their safety is the focus of many people's attention. In particular, most of the domestic toilets are dry and wet without separation, and smart toilets are plugged in and operated in a humid environment, which carries certain safety risks. However, when purchasing, the safety factor of the smart toilet cannot be seen purely from the appearance, however, there are still some points to refer to.

    Safety must-see: look at leakage protection devices and grounding measures.

    Smart toilets are products that combine water and electricity, and must have corresponding leakage protection devices and compliant grounding treatment. Usually, mainstream brands of smart toilets have multiple leakage protection devices, once the voltage is abnormal, it will automatically cut off the power, and you can guide the buyer to ask if there is this function when purchasing.

    In addition, if a smart toilet does not have compliant grounding measures, the user is at risk of electric shock. According to the national standard, the easily accessible metal parts on the smart toilet should be permanently and reliably connected to the grounding terminal, or to the grounding contact of the input jack, and the clamping device of the grounding terminal should be reliable and firm. When purchasing, check whether there is a ground terminal near the lead end of the power cable.

    If necessary, a test pen can be used for leakage detection.

    Safety must-see: look at the waterproof measures.

    In order to prevent water from splashing out and causing safety accidents such as short circuit, fire, and leakage of smart toilet appliances, the qualified waterproof protection level of smart toilet should at least reach the splash-proof type (IPX4), and products below this level should not be purchased.

    Safety must-see: look at the flame retardant grade of the material.

    When buying a smart toilet, you can check the product manual or national safety test certificate to see if the materials used have flame retardants added. There are three levels of flame retardant grades: V-0, V-1, V-2, among which V-0 has the best flame retardant effect, even if an accident occurs, the product is not combustible.

  8. Anonymous users2024-01-16

    The smart toilet is quite safe, there are multiple safety protection devices, as long as the ground is intact at home, the function is normal, and the leakage is basically impossible, and the judgment Jing Ying has not even heard of digging in the news, indicating that this matter has basically not happened, you think too much about the manuscript cluster, if you are too worried, you can dial the plug, so there is just no heating function.

  9. Anonymous users2024-01-15

    Hello! If you are worried about the leakage of the smart toilet, you should pay attention to it, and the smart toilet is still safe to use, so don't hurt people.

Related questions
12 answers2024-04-26

Water leakage should not be, and electricity leakage should not be! The solution to the problem is to contact the merchant immediately to return the product! This is an electrical product that is in direct contact with the human body, and the design of their products is not good, and cutting corners such as safety protection switches is even more dangerous!

6 answers2024-04-26

Summary. Hello, dear, your question is answered as follows. If the product meets the use standard, it can continue to be used, and if it cannot meet the continued use of electricity, it needs to be considered to be replaced. >>>More

7 answers2024-04-26

Directly find the brand after-sales ah, smart toilet maintenance is more troublesome, unlike ordinary toilets, many accessories can be universal, most of the electronic parts of different brands are not universal, unless you do not have this brand of after-sales in your local area, buy smart toilets This kind of high-end things must choose a more well-known brand, quality and after-sales can keep up, or find a local store to buy from a larger business, at least large merchants are not easy to close, can deal with after-sales.

6 answers2024-04-26

The blockage of the smart toilet is also a blockage at the trap; The best and easiest way to do it is ... >>>More

6 answers2024-04-26

You're worrying too much, you don't imagine that the world or the sky is going to fall, because the sky is falling and the house is on top, and there are other things on top.