The new house gas meter and kitchen are not in the same room can be bar, the table and living room a

Updated on Kitchen 2024-03-27
2 answers
  1. Anonymous users2024-01-23

    Gas meters and stoves can not be installed in one room, the state has regulations, gas pipes and meters are not installed in one room with people staying in the place.

    In addition, light and dark wires and power sockets should not be installed near the gas pipeline, and the horizontal net distance from the gas pipeline should be kept greater than 30 cm. There shall be no wires and electrical equipment within 10 cm of the gas meter, and the horizontal distance between the stove and the gas meter shall not be less than 30 cm. The low epitope should not be lower than the meter, the middle epitope is to the meter, and the high epitope is above the meter.

    Finally, the simple installation standard:

    1. The gas meter should be installed behind the main valve of the household.

    2. The installation of the gas meter should meet the requirements of meter reading, overhaul, maintenance and safe use.

    3. When the gas meter is installed above the gas cooker, the horizontal net distance between the gas meter and the gas stove shall not be less than 300mm.

    4. The gas meter should be installed in a non-combustible structure and a well-ventilated room.

    5. Gas meters are strictly forbidden to be installed in bathrooms, bedrooms, dangerous goods and flammable materials.

  2. Anonymous users2024-01-22

    Solved, can a meter and a gas stove be installed in two different rooms? I also had a similar problem, ask for help.

Related questions
1 answers2024-03-27

It is normal that sometimes in order to facilitate maintenance, for thermal expansion and contraction, there will be a joint, and it cannot be all one tube. As long as it is not a sealed environment, it is still safe.

2 answers2024-03-27

Oxygen consumption is relatively high, pay attention to preservation and ventilation.

2 answers2024-03-27

Generally, the installation standards of gas alarms are the same, in order to make the alarm in the best working condition, there are several precautions: >>>More

8 answers2024-03-27

Natural gas, kitchen and two toilets can be equipped with water heaters. The specific installation method is as follows: >>>More

3 answers2024-03-27

Open kitchens cannot be ventilated mainly because they do not meet the relevant design codes. "Technical Specifications for Urban Gas" (GB50494-2009) stipulates"Residential gas appliances should not be installed in bedrooms. Combustion appliances should be installed in well-ventilated, well-ventilated kitchens or non-living rooms. >>>More