What is the distance between the floor heating pipe in the living room and the partition wall in the

Updated on Living room 2024-03-11
8 answers
  1. Anonymous users2024-01-23

    THE DISTANCE BETWEEN THE FLOOR HEATING PIPE IN THE LIVING ROOM AND THE PARTITION WALL IN THE KITCHEN IS GENERALLY 10 TO 15 CM.

  2. Anonymous users2024-01-22

    Generally, it is made 15 cm from the wall, and some are 10 cm.

  3. Anonymous users2024-01-21

    Kitchen things, durability is king, Oppai cabinets, Simi cabinets, Boloni and other first-line brands are reliable.

  4. Anonymous users2024-01-20

    Traditional floor heating doors and windows are generally encrypted at a distance of 15-20 cm, and other areas are at 20-25 cm.

  5. Anonymous users2024-01-19

    It is best to do a good job of partition wall before doing floor heating, or set the position in advance, leave it when laying floor heating, if it is a brick base, if it is gypsum board or something, pay attention not to have nails on the floor heating pipe.

  6. Anonymous users2024-01-18

    1. The distance between the floor heating coil and the wall is generally about the same as that of other places.

    2. General: the coil is 20, and the spacing of the coil will be a little larger at 15 to 20 cm. THE COIL IS 16 CM AND GENERALLY IS BETWEEN 10 AND 15 CM.

    3. In the construction, if you look at the standard wall, the spacing of different places may be 1 to 3cm. So pay attention when you want to move. Drawings are just for reference

  7. Anonymous users2024-01-17

    The distance between the floor heating pipe and the wall is generally 15 cm. The walls should also be cut with boundary insulation strips so that the heat does not spread to the walls. So as long as the interval is 15 cm, it will be fine to do the upper boundary insulation strip. Hope it helps.

  8. Anonymous users2024-01-16

    There is no clear rule for this, and it is generally the designer who chooses according to the style of the design.

Related questions
3 answers2024-03-11

Basically, the switches are against the wall, and they can be wrapped in cabinets without tiles.

2 answers2024-03-11

One thing to pay attention to is that the pipe out of the water separator should be insulated about one meter and a half to prevent the cracking of the tiles caused by the high local temperature.

4 answers2024-03-11

1. Check whether there is leakage; 2. Close the doors and windows, increase the room temperature, and gradually dissolve the ice in the floor heating pipe; 3. After the floor heating pipe is melted, check again for water leakage. If there is no leakage, you can try to suppress it again, which is the safest. If there is a leak, it is necessary to find the leak and dig the ground for bonding and repair.

3 answers2024-03-11

Avoid the floor drain on the ground, drains, etc. can be laid, my family found Beijing Glanxuan kitchen, bathroom installed, each room is warm.

5 answers2024-03-11

Today's floor heating installation will go through strict water and pressure tests If there is a leakage problem found in the monitoring 24 hours, it will be dealt with in time. Personally, it is recommended to install floor heating equipment or choose a big brand, so that the maintenance and after-sales service will be more quality assurance; If you don't know how to install, don't start at will, just spend money to hire a professional person to do professional things.