Why is the kitchen short circuited, the empty opening tripping at home, and the meter box is always

Updated on Kitchen 2024-03-17
5 answers
  1. Anonymous users2024-01-23

    Hello: 1, the air switch is in [Under the impact of short-circuit current ], it will definitely trip for protection.

    2. The air switch is [Nominal current value ] should be configured reasonably, when the unit air switch and the meter box air switch [The capacity is the same ], such a fault phenomenon will occur.

    3. Reasonable allocation of the capacity of the air switch is one of the basic measures for safe electricity use.

  2. Anonymous users2024-01-22

    This is a skipping trip.

    According to the regular standard, the action current of the next level of air opening and the air opening of the upper stage is different, and there is a time difference between tripping. The circuit used in the home, no one counts the short-circuit current, calculates the tuning, and then selects the device. Often there is a fault can be tripped on the line.

  3. Anonymous users2024-01-21

    This situation is a common occurrence in the power distribution circuit when the switch trips over the level.

    Indicate that your kitchen short-circuit current (or leakage current) is too large and has caused the two-stage switch to trip.

    Check how much current your kitchen switch and the main switch of the meter are, and whether they have leakage protection. The cause of the trip should be analyzed according to the switch configuration.

    Under normal circumstances, the kitchen air opening current should be less than the total air opening current, in this case, if there is an overcurrent, jump the kitchen switch first, and then jump the main switch.

    If there is a short-circuit current in the electrical circuit, and the short-circuit current is relatively large, it is easy to cause the two-stage switch to trip at the same time, which is a normal protection trip.

  4. Anonymous users2024-01-20

    The speed of the empty opening trip at home to cut off the short-circuit point is not fast enough, and the current speed is close to the speed of light, causing the total empty opening of the meter box to flow through the short-circuit current, which acts on the tripping.

  5. Anonymous users2024-01-19

    Generally, the air opening has the function of short-circuit tripping, and the respective tripping curves are not the same, so many short-circuit faults are isolated by jumping one level of air opening. However, there are also a lot of short-circuit faults that jump multi-level empty open or this level of empty open does not jump, jump upper air open, which is caused by improper air open selection, their rated current is about the same, the trip curve is too similar, or the air open of the upper level is more sensitive.

Related questions
2 answers2024-03-17

Is your 25A air switch connected to the wrong wiring, the lower joint of the 25A air switch is connected to the zero line, when the kitchen air switch is closed, the zero line of the air switch (below the contact) and the live wire (the upper contact) are connected, it trips, when the 25A air switch is disconnected, the zero line is not connected with the live wire, so it is normal. >>>More

3 answers2024-03-17

In this case, most of the faults are leakage. It is difficult to deal with irregular tripping, because of this kind of leakage fault, the leakage current is not very large. If it is said that the leakage switch jumps down as soon as it is powered, it is very simple. >>>More

3 answers2024-03-17

Find the plumber who renovated your home to deal with it.

1 answers2024-03-17

【4 square wires】No problem;

The air opening is C16A] There is a problem. The air switch is too small. >>>More

5 answers2024-03-17

You mean to say. Only the kitchen in your house is out of power, and the kitchen branch switch is not jumping, but the zero loop above the empty open is also electrified? Answer. >>>More