How to change the equipotential of the bathroom

Updated on Bathroom 2024-03-20
1 answers
  1. Anonymous users2024-01-23

    Talk about all the metal parts in the bathroom, (metal pipes, metal faucets, electric water heaters to metal shells, shower head mixing water valves, metal drains, floor drains, metal brackets, etc.) using metal strips (copper wires, stainless metal steel bars, etc.) and connect together, connected to the equipotential metal bus terminal, and then from the equipotential bus bar using a wire to connect to the equipotential metal bar of the protective grounding wire of the distribution box, the detection and blocking is not more than 4 ohms on the qualified ---

Related questions
7 answers2024-03-20

When it comes to equipotential, many people may know a little bit about it, but it is a device that can protect your life and age. So the question is, do you know how to connect the equipotential in the bathroom? What is the construction standard for equipotential installation? >>>More

1 answers2024-03-20

The power cord in the wall is generally worn in the line tube, even if the insulation skin is damaged, it will not cause the wall to be electrified, when the power line has leakage, the leakage protection circuit breaker will trip, there is an equipotential device, the best use of the hand bucket is appropriate, the faucet shower mixed with water Qi Shi switch and other metal parts with Bi Mo wire and equipotential metal row in one.

2 answers2024-03-20

The installation perimeter of the complete set of distribution boxes.

1 answers2024-03-20

To put it simply, it is the grounding wire, as long as the wire is connected, it is generally fine, and it can be sealed with bricks. >>>More

1 answers2024-03-20

1.Weld 25*4 galvanized flat steel from the bottom plate steel mesh and lead it out to the local equipotential box of the wall. >>>More