If you want to add a bathroom to the master bedroom, please ask for advice

Updated on Master bedroom 2024-03-18
11 answers
  1. Anonymous users2024-01-23

    If you want to increase the bathroom, you need to do the sewer, the diameter of the sewer pipe is thicker, and there needs to be a certain slope (generally 5 degrees), which needs to raise the ground to solve this problem, generally it should be at 150MM, and then punch holes in the wall from the low end, and the pipe can enter the bathroom, but the added toilet can only take a bath at most to solve the problem of urine, and the stool can not be solved.

  2. Anonymous users2024-01-22

    Your idea is good, but you have to be realistic. If you live on the ground floor, there may be scope for alterations – but also have a professional design and installation done with permits. But if you live upstairs, there is no possibility of remodeling!

    Because the water supply problem of the bathroom is easy to solve, but its drainage cannot be done, such as: where to put the drainage pipe, how to install it, the impact on the downstairs neighbors, etc.

  3. Anonymous users2024-01-21

    It is necessary to solve the problems of water supply and drainage, mainly three aspects: drainage, sewage discharge, and waterproofing.

    The problem is the biggest and more difficult, and not only is it structurally infeasible for the sewage pipe to pass through the floor slab, but the downstairs neighbors will also object because it violates the provisions of the design code.

    Raising the ground to make a horizontal sewage pipe on the floor slab will cause you trouble in the future, and increasing the floor load and easy blockage are two major obstacles.

    The other two problems (waterproofing and water supply) can be solved technically, and the solution of putting a shower or bathtub in the bedroom is feasible.

  4. Anonymous users2024-01-20

    If you want to add a bathroom close to other bathrooms, it is easy to solve. Raise the part of the bathroom you want to add to the master bedroom, and drain it into the next bathroom.

  5. Anonymous users2024-01-19

    The landlord will send out the floor plan of your house to see.

  6. Anonymous users2024-01-18

    Feng Shui says that it is best not to have a bathroom in the bedroom.

  7. Anonymous users2024-01-17

    If the bedroom is close to the bathroom, this problem is very easy to solve, because you want to increase the bathroom to do sewer, the diameter of the sewer pipe is thicker, and there needs to be a certain slope (generally 5 degrees), which needs to raise the ground to solve this problem, if your bedroom is far away from the indoor bathroom, then this problem is difficult to solve, the floor is impossible to groove to make drainage! The longer the drain pipe, the higher the ground elevation, so it is not possible to cross other spaces to make the floor drainage problem. If it is close to the indoor bathroom, this problem is relatively simple, because the increased bathroom floor height can be increased, generally should be at 150MM, and then punch holes in the wall from the low end, and the pipe can enter the bathroom, but the added bathroom can only take a bath at most to solve the problem of urine, and the stool can not be solved, the reason is relatively simple, the toilet pipe can not communicate with the lower pipe of the bathroom, if the communication requires that the height of your room must be more than three meters, otherwise it cannot be done.

    Other construction problems are that the wall must be made of bricks, waterproof to achieve a meter height, the problem of water is better solved, you can walk the ground or the ceiling. In short, it depends on the basic conditions of your house, not all buildings can be built with bathrooms at will. I hope the answer is inspiring to you.

  8. Anonymous users2024-01-16

    First of all, it is illegal to add a bathroom to the master bedroom.

    According to the Ministry of Construction of the People's Republic of China on the "Administrative Measures for Residential Interior Decoration" Chapter 2 Article 5 stipulates that residential interior decoration activities, the following behaviors are prohibited:

    A) without the original design unit or the design unit with the corresponding qualification level to put forward the design plan, change the main body of the building and load-bearing structure;

    2) Changing rooms or balconies without waterproof requirements into bathrooms and kitchens;

    3) Expand the size of the original doors and windows on the load-bearing wall, and remove the brick and concrete walls connecting the balconies;

    4) Damage the original energy-saving facilities of the house and reduce the energy-saving effect;

    5) Other behaviors that affect the safety of building structure and use.

    Violated Articles 1, 2, 5 respectively.

    Secondly, adding a toilet to the master bedroom is extremely unethical and self-serving.

    The sound of the toilet flushing. It will seriously affect the rest of the downstairs bedroom owner.

    There is a risk of water leakage.

    It's unlucky. How would you feel if someone was in your place to rest and sleep, or on top of your head, pooping and peeing every day?

    PS: It is recommended that the majority of householders If they find that there is an act of adding a toilet in the process of renovation upstairs, it is recommended to call the urban management directly, or the property, if these do not work, go directly to the court to complain. There can be no softness in dealing with this kind of person who adds a toilet in the bedroom.

    You can't eat hard or soft. There was only one condition for the settlement, and that was to remove the toilet that had been added after the bedroom.

  9. Anonymous users2024-01-15

    Why not, as long as it doesn't affect the downstairs, the house is also built by people, you can use the pattern you want. Some designers have just graduated from college and have not actually practiced, and the design pattern may not meet the requirements of people's lives, and problems such as convenience appear.

  10. Anonymous users2024-01-14

    Whether your home is your own house or a commercial house, the master bedroom is on the 2nd floor or above the 2nd floor, and it is very troublesome on the 1st floor. If you are a commercial house, you also have to ask the landlord of the floor below the property, because the bathroom has to go down the drain.

  11. Anonymous users2024-01-13

    The other two problems (waterproofing and water supply) can be solved technically, and the solution of putting a shower or bathtub in the bedroom is feasible. If you only take a bath, you can, but if you add a toilet, you can't do it, and you can't add it hard.

Related questions
4 answers2024-03-18

If you want to increase the bathroom, you need to do the sewer, the diameter of the sewer pipe is thicker, and there needs to be a certain slope (generally 5 degrees), which needs to raise the ground to solve this problem, generally it should be at 150MM, and then punch holes in the wall from the low end, and the pipe can enter the bathroom, but the added toilet can only take a bath at most to solve the problem of urine, and the stool can not be solved.

2 answers2024-03-18

The suggestion is that the kitchen door should not be changed, the bathroom door can be changed to the corner of the hall, and the living room is recommended not to be separated, it is not good to become a dark hall.

1 answers2024-03-18

In the process of transforming hydropower and electricity, we must preserve the original waterproof layer structure. In addition, when we need a new waterproof layer, we must choose a good waterproof material, which can make the decoration better, in addition to the process of waterproof operation, do not operate in rainy days, so that you can not see the waterproof effect, do a good job of waterproofing the wall, we must at least 30 cm high wall waterproof treatment. >>>More

2 answers2024-03-18

It's a ...... to prepare for a thesis or an assignment

The guest room is the most direct place for the customer experience, and it is also the most intuitive manifestation of the hotel's own brand image, which is directly related to the source of guests. >>>More

2 answers2024-03-18

It is feasible from the diagram, but the specific construction from the riser to open three passes, the construction still needs to find an experienced master, it is recommended that you raise 15 cm from the supervisor to the new toilet together, so that the construction is more convenient, not easy to leak, and it is not easy to block when used in the future, please accept it.