How much area of the restaurant needs to be equipped with fire sprinklers?

Updated on Restaurant 2024-01-27
7 answers
  1. Anonymous users2024-01-23

    More than 300 square meters need to be equipped with fire sprinklers.

    Generally, only commercial, office, super high-rise, and public buildings need to install fire sprinklers indoors. However, if the fire inspection department considers that the residential design of the building exceeds the standard (e.g. the total height of the floor exceeds 100 meters, the commercial area of the first and second floors exceeds 300 square meters, etc.), the developer must install fire sprinklers for each household.

    According to the Code for Fire Protection Design of High-rise Civil Buildings (2005 Edition) (GB50045-95), if it is a pure residence, there is no need to install fire sprinklers indoors; If the upper floor is a residential ground floor for commercial, it does not need to be installed inside the residence; But if it is a serviced apartment, then it must be installed in every house.

  2. Anonymous users2024-01-22

    Each 10 20 square meters of the range is arranged with a sprinkler head. The design principle of the fire sprinkler system is to determine the number and type of sprinkler heads according to the area of the place of use and the object of fire protection.

    Wet systems can be used in buildings and places where the ambient temperature is not lower than 4 and not higher than 70 (except for buildings and places where water cannot be extinguished). When the system is applied locally, it is suitable for the area that needs local protection in the light hazard or medium hazard level in the civil building where the maximum indoor clearance height does not exceed 8m and the total construction area does not exceed 1000.

  3. Anonymous users2024-01-21

    More than 200 square meters.

    1. The drooping sprinkler is the most widely used sprinkler, which is installed on the water supply branch pipe by sagging, and the shape of the sprinkler is a parabolic shape, spraying 80 100% of the total water volume to the ground. To protect the room with a suspended ceiling, a sprinkler head should be arranged under the ceiling, and a drooping sprinkler head or a ceiling-type sprinkler head should be used.

    2. The upright sprinkler head is installed upright on the water supply branch pipe, and the sprinkling shape is a parabolic shape, and 80 100% of the total amount of water is sprayed downward, and at the same time, the upright sprinkler head is also partially sprayed to the ceiling, which is suitable for installation in places with more moving objects and easy to impact, such as warehouses, and can also be concealed in the roof of the room ceiling mezzanine to protect the boron of the ceiling with more flammable materials. (In places where the ceiling is not made, when the water distribution branch pipe is arranged under the beam, the upright type should be used.) For areas that are susceptible to collisions, a sprinkler head with a protective cover or a ceiling-type sprinkler should be used).

    3. The ordinary sprinkler head can be installed directly, or it can be installed on the sprinkler pipe network, spraying 40%-60% of the total water volume downward, and spraying a larger part to the ceiling. It is suitable for restaurants, shops, warehouses, underground garages and other places. (Less common type).

    4. The side wall type sprinkler is installed against the wall, which is suitable for installation in places where the space pipe is difficult, and is mainly used in the light and dangerous parts of buildings such as offices, halls, lounges, corridors, guest side wall sprinkler head rooms, etc. The roof is a light hazard and medium hazard class I room and office with a horizontal plane, and a side wall type sprinkler can be used.

  4. Anonymous users2024-01-20

    In the "Building Regulations", catering establishments with a business area of more than 500 m2 in public buildings shall be equipped with automatic fire extinguishing devices in the exhaust hood and cooking parts of the cooking operation room, and automatic emergency shut-off devices shall be installed on gas or fuel pipelines.

  5. Anonymous users2024-01-19

    Hello is honored to serve you, according to the provisions of relevant national laws and regulations, the requirements for restaurant fire sprinkler facilities are as follows:1Restaurants with an area of more than 200 square meters and densely populated areas (such as restaurant halls, private rooms, etc.) need to be equipped with fire sprinkler systems.

    2.Kitchens and storage areas also generally need to be equipped with sprinkler systems in fire banquets. 3.

    Unless there is a fire or other special circumstances in the restaurant, the fire sprinkler system shall not be turned off at will. These regulations may vary and should be determined according to local fire regulations. Therefore, it is recommended that when you renovate your restaurant, it is important that you understand the relevant local regulations and design and construct them in accordance with the regulations.

  6. Anonymous users2024-01-18

    According to the national standard "Code for Fire Protection Design of Buildings" (GB50016-2014), the requirements for the fire sprinkler system of the area size of the restaurant are as follows: 1If the restaurant area is more than 500, an automatic sprinkler system should be installed.

    2.If the area of the restaurant is less than 500 meters, if the height of the building does not exceed 24m and the purpose is a general public building, the automatic sprinkler system can not be installed; If the height of the building exceeds 24m, or if it is used as a high-rise public building, it is still necessary to install a sprinkler system.

  7. Anonymous users2024-01-17

    Summary. Hello dear <>

    The restaurant has a large area of more than 300 square meters and needs to be equipped with fire sprinklers.

    How much area of the restaurant needs to be equipped with fire sprinklers?

    Hello dear <>

    The restaurant has a large area of more than 300 square meters and needs to be equipped with fire sprinklers.

    Generally, only commercial, office, super high-rise, and public buildings need to install fire sprinklers indoors. However, if the fire inspection department considers that the residential design of the building exceeds the standard (e.g. the total height of the floor exceeds 100 meters, the commercial area of the first and second floors exceeds 300 square meters, etc.), the developer must install fire sprinklers for each household. According to the provisions of the Code for Fire Protection Design of High-rise Civil Buildings (2005 Edition) (GB50045-95), if it is a pure residence, there is no need to install fire sprinklers indoors; If the upper floor is a residential ground floor for commercial, it does not need to be installed inside the residence; But if it is a serviced apartment, then it must be installed in every house.

    Extended information: The working principle of the fire sprinkler system: 1. Closed fire sprinkler system:

    Usually the roof fire water tank is filled with water, when a fire occurs, the sprinkler head is prepared to melt after the temperature reaches a certain temperature (generally 68 °C), the water in the pipe is automatically sprayed out under the action of the water pressure of the fire water tank, at this time, the wet report Wang Roll false alarm valve is automatically opened, the pressure switch in the valve is automatically opened, and the pressure switch has a signal line and the fire pump is interlocked, and the pump will start automatically. 2. Open fire sprinkler system: the system is equipped with a smoke detector to detect the smoke, when the smoke reaches a certain concentration, the smoke detector alarms, and the host confirms that it is fed back to the sound and light alarm action, and the sound or flashing lights warn people, and the linkage smoke exhaust fan is started to start the smoke exhaust, and the solenoid valve of the rain deer valve is opened at the same time, and the water is sprayed directly by the open sprinkler head in the linkage spray pump.

    I wish you a happy life! Hope mine is helpful to you ha.

    The upstairs is a business building, and the restaurant is 180 square meters, do you need to install it?

    In both cases, a sprinkler system needs to be set up. One is that the hotel is in the podium or outlet room of the high-rise building or high-rise residential area, or the building itself is equipped with an automatic sprinkler system, then the hotel must continue to improve the sprinkler system. Another situation is that the building area of the hotel is more than 3,000 square meters or the area of the ground is more than 1,500 square meters, and the sprinkler system needs to be installed.

Related questions
5 answers2024-01-27

Generally 4-6 square meters, if the number of its own flat is large, the bathroom must be correspondingly larger, my two bathrooms cover an area of 10 square meters......-The decoration said that my bathroom is too big and a bit of a waste of space.

1 answers2024-01-27

20 square Choose a 48W square or round one.

If you want to be rectangular, the size is 840x620mm and it is 72W. >>>More

1 answers2024-01-27

It is according to the number of people designed. It may be necessary to convert it in terms of area. >>>More

3 answers2024-01-27

If you find that the wallpaper changes color not long after you move in, it is because the wallpaper is still dry and pasted, and the alkaline nature of the wall is easy to chemically react with the bottom of the wallpaper, making the surface appear yellow, which is more difficult to deal with. >>>More

1 answers2024-01-27

According to the board calculation, of course, the price will be relatively cheaper, with a 55-70 yuan price, of course, the price can be higher 20---30 square building owners of a square area contract, a 3 square meters, then it is about 20 yuan a square, gardener decoration.